"Hemostatics" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Agents acting to arrest the flow of blood. Absorbable hemostatics arrest bleeding either by the formation of an artificial clot or by providing a mechanical matrix that facilitates clotting when applied directly to the bleeding surface. These agents function more at the capillary level and are not effective at stemming arterial or venous bleeding under any significant intravascular pressure.
Descriptor ID |
D006490
|
MeSH Number(s) |
D27.505.954.502.270.463
|
Concept/Terms |
|
Below are MeSH descriptors whose meaning is more general than "Hemostatics".
Below are MeSH descriptors whose meaning is more specific than "Hemostatics".
This graph shows the total number of publications written about "Hemostatics" by people in this website by year, and whether "Hemostatics" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
1999 | 1 | 0 | 1 |
2001 | 0 | 1 | 1 |
2002 | 0 | 2 | 2 |
2003 | 4 | 0 | 4 |
2004 | 1 | 1 | 2 |
2006 | 0 | 1 | 1 |
2007 | 2 | 0 | 2 |
2008 | 1 | 0 | 1 |
2009 | 3 | 1 | 4 |
2010 | 3 | 0 | 3 |
2011 | 4 | 0 | 4 |
2012 | 4 | 0 | 4 |
2013 | 1 | 0 | 1 |
2014 | 1 | 0 | 1 |
2015 | 2 | 0 | 2 |
2017 | 1 | 0 | 1 |
2018 | 1 | 0 | 1 |
To return to the timeline,
click here.
Below are the most recent publications written about "Hemostatics" by people in Profiles.
-
Schauer SG, April MD, Naylor JF, Maddry JK, Arana AA, Dubick MA, Fisher AD, Cunningham CW, Pusateri AE. Prehospital Application of Hemostatic Agents in Iraq and Afghanistan. Prehosp Emerg Care. 2018 Sep-Oct; 22(5):614-623.
-
Schauer SG, April MD, Naylor JF, Fisher AD, Cunningham CW, Ryan KL, Thomas KC, Brillhart DB, Fernandez JRD, Antonacci MA. QuikClot® Combat Gauze® Use by Ground Forces in Afghanistan The Prehospital Trauma Registry Experience. J Spec Oper Med. 2017 Summer; 17(2):101-106.
-
Hanna JM, Keenan JE, Wang H, Andersen ND, Gaca JG, Lombard FW, Welsby IJ, Hughes GC. Use of human fibrinogen concentrate during proximal aortic reconstruction with deep hypothermic circulatory arrest. J Thorac Cardiovasc Surg. 2016 Feb; 151(2):376-82.
-
Garcia-Blanco J, Gegel B, Burgert J, Johnson S, Johnson D. The Effects of Movement on Hemorrhage When QuikClot® Combat Gauze™ Is Used in a Hypothermic Hemodiluted Porcine Model. J Spec Oper Med. 2015; 15(1):57-60.
-
Johnson D, Westbrook DM, Phelps D, Blanco J, Bentley M, Burgert J, Gegel B. The effects of QuikClot Combat Gauze on hemorrhage control when used in a porcine model of lethal femoral injury. Am J Disaster Med. 2014; 9(4):309-15.
-
Gegel BT, Austin PN, Johnson AD. An evidence-based review of the use of a combat gauze (QuikClot) for hemorrhage control. AANA J. 2013 Dec; 81(6):453-8.
-
Gegel B, Burgert J, Gasko J, Campbell C, Martens M, Keck J, Reynolds H, Loughren M, Johnson D. The effects of QuikClot Combat Gauze and movement on hemorrhage control in a porcine model. Mil Med. 2012 Dec; 177(12):1543-7.
-
Johnson D, Agee S, Reed A, Gegel B, Burgert J, Gasko J, Loughren M. The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution. US Army Med Dep J. 2012 Oct-Dec; 36-9.
-
Gegel B, Burgert J, Loughren M, Johnson D. The effects of BleedArrest on hemorrhage control in a porcine model. US Army Med Dep J. 2012 Oct-Dec; 31-5.
-
Burgert J, Gegel B, Neal AR, Kammer KE, Paul ME, Schwartz DJ, Loughren M, Johnson A. The effects of arterial blood pressure on rebleeding when BleedArrest, Celox and TraumaDex are used in a porcine model of lethal femoral injury. Mil Med. 2012 Mar; 177(3):340-4.