Brian Gegel to Animals
This is a "connection" page, showing publications Brian Gegel has written about Animals.
Connection Strength
0.275
-
The effects of QuikClot Combat Gauze on hemorrhage control when used in a porcine model of lethal femoral injury. Am J Disaster Med. 2014; 9(4):309-15.
Score: 0.033
-
An evidence-based review of the use of a combat gauze (QuikClot) for hemorrhage control. AANA J. 2013 Dec; 81(6):453-8.
Score: 0.033
-
The effects of QuikClot Combat Gauze and movement on hemorrhage control in a porcine model. Mil Med. 2012 Dec; 177(12):1543-7.
Score: 0.031
-
The effects of BleedArrest on hemorrhage control in a porcine model. US Army Med Dep J. 2012 Oct-Dec; 31-5.
Score: 0.030
-
The effects of BleedArrest, Celox, and TraumaDex on hemorrhage control in a porcine model. J Surg Res. 2010 Nov; 164(1):e125-9.
Score: 0.026
-
Effects of Celox and TraumaDEX on hemorrhage control in a porcine model. AANA J. 2010 Apr; 78(2):115-20.
Score: 0.026
-
Effects of intravenous, sternal, and humerus intraosseous administration of Hextend on time of administration and hemodynamics in a hypovolemic swine model. Am J Disaster Med. 2016; 11(3):183-192.
Score: 0.010
-
The Effects of Movement on Hemorrhage When QuikClot? Combat Gauze? Is Used in a Hypothermic Hemodiluted Porcine Model. J Spec Oper Med. 2015; 15(1):57-60.
Score: 0.009
-
Effects of sternal intraosseous and intravenous administration of Hextend on time of administration and hemodynamics in a swine model of hemorrhagic shock. Am J Disaster Med. 2015; 10(1):61-7.
Score: 0.009
-
The pharmacokinetics of intraosseous atropine in hypovolemic swine. Am J Disaster Med. 2015; 10(3):217-22.
Score: 0.009
-
Effects of intraosseous transfusion of whole blood on hemolysis and transfusion time in a swine model of hemorrhagic shock: a pilot study. AANA J. 2014 Jun; 82(3):198-202.
Score: 0.009
-
Effects of intraosseous and intravenous administration of Hextend? on time of administration and hemodynamics in a Swine model. J Spec Oper Med. 2014; 14(1):79-85.
Score: 0.008
-
Comparison of muscle paralysis after intravenous and intraosseous administration of succinylcholine in Swine. J Spec Oper Med. 2014; 14(2):35-37.
Score: 0.008
-
The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution. US Army Med Dep J. 2012 Oct-Dec; 36-9.
Score: 0.008
-
Comparison of tibial intraosseous, sternal intraosseous, and intravenous routes of administration on pharmacokinetics of epinephrine during cardiac arrest: a pilot study. AANA J. 2012 Aug; 80(4 Suppl):S6-10.
Score: 0.008
-
The effects of arterial blood pressure on rebleeding when BleedArrest, Celox and TraumaDex are used in a porcine model of lethal femoral injury. Mil Med. 2012 Mar; 177(3):340-4.
Score: 0.007
-
Effects of arterial blood pressure on rebleeding using Celox and TraumaDEX in a porcine model of lethal femoral injury. AANA J. 2010 Jun; 78(3):230-6.
Score: 0.006
-
Effects of the HEET garment in the prevention of hypothermia in a porcine model. J Surg Res. 2010 Nov; 164(1):126-30.
Score: 0.006