Michael Gold to Death, Sudden, Cardiac
This is a "connection" page, showing publications Michael Gold has written about Death, Sudden, Cardiac.
Connection Strength
10.900
-
Can We Treat an Older Patient With a New Trick? J Am Coll Cardiol. 2022 03 22; 79(11):1060-1062.
Score: 0.704
-
Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial. Circulation. 2021 01 05; 143(1):7-17.
Score: 0.638
-
Relationship of Shock Energy to Impedance During Subcutaneous Implantable Cardioverter-Defibrillator Testing. Circ Arrhythm Electrophysiol. 2020 09; 13(9):e008631.
Score: 0.627
-
Outcomes of subcutaneous implantable cardioverter-defibrillator in dialysis patients: Results from the S-ICD post-approval study. Heart Rhythm. 2020 09; 17(9):1566-1574.
Score: 0.618
-
Electromagnetic interference from left ventricular assist devices in patients with subcutaneous implantable cardioverter-defibrillators. J Cardiovasc Electrophysiol. 2020 05; 31(5):1195-1201.
Score: 0.611
-
Understanding Outcomes with the EMBLEM S-ICD in Primary Prevention Patients with Low EF Study (UNTOUCHED): Clinical characteristics and perioperative results. Heart Rhythm. 2019 11; 16(11):1636-1644.
Score: 0.577
-
Subcutaneous implantable cardioverter-defibrillator Post-Approval Study: Clinical characteristics and perioperative results. Heart Rhythm. 2017 10; 14(10):1456-1463.
Score: 0.502
-
The Design of the Understanding Outcomes with the S-ICD in Primary Prevention Patients with Low EF Study (UNTOUCHED). Pacing Clin Electrophysiol. 2017 Jan; 40(1):1-8.
Score: 0.492
-
Safety and Efficacy of the Subcutaneous Implantable Defibrillator. J Am Coll Cardiol. 2016 Feb 02; 67(4):445-454.
Score: 0.460
-
A new algorithm to reduce inappropriate therapy in the S-ICD system. J Cardiovasc Electrophysiol. 2015 Apr; 26(4):417-423.
Score: 0.431
-
Newer Indications for ICD and CRT. Cardiol Clin. 2014 May; 32(2):181-90.
Score: 0.402
-
How many transvenous coils are optimal for defibrillators: one, two, or none? Heart Rhythm. 2013 Jul; 10(7):977-8.
Score: 0.380
-
Economic implications and cost-effectiveness of implantable cardioverter defibrillator and cardiac resynchronization therapy. Heart Fail Clin. 2011 Apr; 7(2):241-50, ix.
Score: 0.329
-
Alcohol consumption and the risk of sudden cardiac death in women: an evaluation from the Nurses' Health Study. Heart Rhythm. 2010 Oct; 7(10):1381-2.
Score: 0.312
-
Risk stratification of ventricular arrhythmias in patients with systolic heart failure. Curr Opin Cardiol. 2010 May; 25(3):268-75.
Score: 0.309
-
Defibrillation testing at ICD implantation: are we asking the wrong question? Pacing Clin Electrophysiol. 2009 May; 32(5):567-9.
Score: 0.288
-
Implantable cardioverter-defibrillator therapy for primary prevention of sudden death after alcohol septal ablation of hypertrophic cardiomyopathy. J Am Coll Cardiol. 2008 Nov 18; 52(21):1718-23.
Score: 0.279
-
Role of microvolt T-wave alternans in assessment of arrhythmia vulnerability among patients with heart failure and systolic dysfunction: primary results from the T-wave alternans sudden cardiac death in heart failure trial substudy. Circulation. 2008 Nov 11; 118(20):2022-8.
Score: 0.278
-
Use of traditional and biventricular implantable cardiac devices for primary and secondary prevention of sudden death. Cardiol Clin. 2008 Aug; 26(3):419-31, vi-vii.
Score: 0.274
-
Sudden cardiac death: the role of risk stratification. Am Heart J. 2007 Apr; 153(4 Suppl):25-33.
Score: 0.249
-
Primary prevention of sudden cardiac death with implantable cardioverter defibrillators: lessons learned from MADIT and MUSTT. Pacing Clin Electrophysiol. 2000 Nov; 23(11 Pt 2):1981-5.
Score: 0.160
-
Editorial commentary: The subcutaneous ICD: An expanding niche or the future of implantable defibrillators? Trends Cardiovasc Med. 2020 08; 30(6):385-386.
Score: 0.149
-
Interaction of septadian and circadian rhythms in life-threatening ventricular arrhythmias in patients with implantable cardioverter-defibrillators. Am J Cardiol. 1999 Sep 01; 84(5):555-7.
Score: 0.147
-
Competitive athletes with implantable cardioverter-defibrillators-How to program? Data from the Implantable Cardioverter-Defibrillator Sports Registry. Heart Rhythm. 2019 04; 16(4):581-587.
Score: 0.139
-
Subcutaneous Versus Transvenous Implantable Defibrillator Therapy: A Meta-Analysis of Case-Control Studies. JACC Clin Electrophysiol. 2017 12 26; 3(13):1475-1483.
Score: 0.129
-
ICD Utilization: Can We Select the Right Patients? JACC Clin Electrophysiol. 2017 03; 3(3):299-301.
Score: 0.124
-
Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication. Heart Rhythm. 2017 03; 14(3):367-375.
Score: 0.122
-
The Role of I-123 Metaiodobenzylguanidine Imaging in Management of Patients With Heart Failure. Am J Cardiol. 2015 Oct 15; 116 Suppl 1:S1-9.
Score: 0.112
-
Clinical experience with subcutaneous implantable cardioverter-defibrillators. Nat Rev Cardiol. 2015 Jul; 12(7):398-405.
Score: 0.109
-
The Post-Myocardial Infarction Pacing Remodeling Prevention Therapy (PRomPT) Trial: Design and Rationale. J Card Fail. 2015 Jul; 21(7):601-7.
Score: 0.108
-
HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. Circulation. 2014 Jul 01; 130(1):94-125.
Score: 0.102
-
Who should receive the subcutaneous implanted defibrillator?: The subcutaneous implantable cardioverter defibrillator (ICD) should be considered in all ICD patients who do not require pacing. Circ Arrhythm Electrophysiol. 2013 Dec; 6(6):1236-44; discussion 1244-5.
Score: 0.099
-
Limitations of ejection fraction for prediction of sudden death risk in patients with coronary artery disease: lessons from the MUSTT study. J Am Coll Cardiol. 2007 Sep 18; 50(12):1150-7.
Score: 0.064
-
Preventing tomorrow's sudden cardiac death today: part I: Current data on risk stratification for sudden cardiac death. Am Heart J. 2007 Jun; 153(6):941-50.
Score: 0.063
-
Preventing tomorrow's sudden cardiac death today: part II: Translating sudden cardiac death risk assessment strategies into practice and policy. Am Heart J. 2007 Jun; 153(6):951-9.
Score: 0.063
-
Seasonal variation of mortality in the Antiarrhythmics Versus Implantable Defibrillators (AVID) study registry. Heart Rhythm. 2004 Oct; 1(4):435-40.
Score: 0.052
-
The influence of gender on arrhythmias. Cardiol Rev. 2004 Mar-Apr; 12(2):97-105.
Score: 0.050
-
T wave alternans for ventricular arrhythmia risk stratification. Curr Opin Cardiol. 2003 Jan; 18(1):1-5.
Score: 0.046
-
T wave alternans: predictor of arrhythmic events? J Cardiovasc Electrophysiol. 2002 May; 13(5):513-4.
Score: 0.044
-
Positive Psychotherapy Improves Cardiac Electrical Stability and Mood in ICD Patients: PAM-ICD Trial Results. Psychosom Med. 2021 04 01; 83(3):300-301.
Score: 0.041
-
Implantable cardiac defibrillators. Med Clin North Am. 2001 Mar; 85(2):343-67, xi.
Score: 0.041
-
A comparison of T-wave alternans, signal averaged electrocardiography and programmed ventricular stimulation for arrhythmia risk stratification. J Am Coll Cardiol. 2000 Dec; 36(7):2247-53.
Score: 0.040
-
Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med. 2000 Jun 29; 342(26):1937-45.
Score: 0.039
-
Evaluation of subcutaneous ICD early performance in hypertrophic cardiomyopathy from the pooled EFFORTLESS and IDE cohorts. Heart Rhythm. 2016 05; 13(5):1066-1074.
Score: 0.029
-
HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. Heart Rhythm. 2014 Jul; 11(7):1271-303.
Score: 0.025
-
HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. J Am Coll Cardiol. 2014 Sep 16; 64(11):1143-77.
Score: 0.025
-
Sport and arrhythmias: summary of an international symposium. Eur J Cardiovasc Prev Rehabil. 2007 Oct; 14(5):707-14.
Score: 0.016