U. Schoepf to Stents
This is a "connection" page, showing publications U. Schoepf has written about Stents.
Connection Strength
1.731
-
Coronary CT angiography-derived quantitative markers for predicting in-stent restenosis. J Cardiovasc Comput Tomogr. 2016 Sep-Oct; 10(5):377-83.
Score: 0.377
-
CT Evaluation of Small-Diameter Coronary Artery Stents: Effect of an Integrated Circuit Detector with Iterative Reconstruction. Radiology. 2015 Sep; 276(3):706-14.
Score: 0.345
-
Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography. Radiology. 2015 May; 275(2):403-12.
Score: 0.339
-
Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility. Eur Radiol. 2023 Apr; 33(4):2469-2477.
Score: 0.147
-
A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography. Eur Radiol. 2016 Dec; 26(12):4380-4389.
Score: 0.092
-
Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study. Eur Radiol. 2016 Jun; 26(6):1871-8.
Score: 0.089
-
CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction. Eur Radiol. 2013 Jan; 23(1):125-32.
Score: 0.072
-
Integrative computed tomographic imaging of coronary artery disease. Expert Rev Cardiovasc Ther. 2011 Jan; 9(1):27-43.
Score: 0.064
-
In vitro evaluation of metallic coronary artery stents with 64-MDCT using an ECG-gated cardiac phantom: relationship between in-stent visualization, stent type, and heart rate. AJR Am J Roentgenol. 2010 Mar; 194(3):W256-62.
Score: 0.061
-
CT of coronary artery disease. J Thorac Imaging. 2007 Feb; 22(1):40-8.
Score: 0.049
-
Pediatric superior vena cava syndrome: assessment at low radiation dose 64-slice CT angiography. J Thorac Imaging. 2006 Mar; 21(1):71-2.
Score: 0.046
-
Quiescent-Interval Slice-Selective MRA Accurately Estimates Intravascular Stent Dimensions Prior to Intervention in Patients With Peripheral Artery Disease. J Magn Reson Imaging. 2022 01; 55(1):246-254.
Score: 0.033
-
Iterative image reconstruction techniques: Applications for cardiac CT. J Cardiovasc Comput Tomogr. 2011 Jul-Aug; 5(4):225-30.
Score: 0.017