Akos Varga-Szemes to Algorithms
This is a "connection" page, showing publications Akos Varga-Szemes has written about Algorithms.
Connection Strength
1.130
-
Determination of infarct size in ex vivo swine hearts by multidetector computed tomography using gadolinium as contrast medium. Invest Radiol. 2012 May; 47(5):277-83.
Score: 0.261
-
Individualized coronary calcium scoring at any tube voltage using a kV-independent reconstruction algorithm. Eur Radiol. 2020 Nov; 30(11):5834-5840.
Score: 0.114
-
Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm. J Cardiovasc Comput Tomogr. 2020 May - Jun; 14(3):246-250.
Score: 0.110
-
A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography. Eur Radiol. 2016 Dec; 26(12):4380-4389.
Score: 0.085
-
Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study. Eur Radiol. 2016 Jun; 26(6):1871-8.
Score: 0.082
-
Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method. Eur Radiol. 2016 May; 26(5):1503-11.
Score: 0.082
-
An Interpretable Chest CT Deep Learning Algorithm for Quantification of COVID-19 Lung Disease and Prediction of Inpatient Morbidity and Mortality. Acad Radiol. 2022 08; 29(8):1178-1188.
Score: 0.032
-
Coronary Computed Tomography Angiography-Based Calcium Scoring: In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System. Invest Radiol. 2022 08 01; 57(8):536-543.
Score: 0.032
-
Optimization of contrast material administration for coronary CT angiography using a software-based test-bolus evaluation algorithm. Br J Radiol. 2022 May 01; 95(1133):20201456.
Score: 0.032
-
Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology. 2019 11; 293(2):260-271.
Score: 0.027
-
Automated plaque analysis for the prognostication of major adverse cardiac events. Eur J Radiol. 2019 Jul; 116:76-83.
Score: 0.026
-
Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection. Eur Radiol. 2019 Sep; 29(9):4783-4793.
Score: 0.026
-
A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions. Eur Radiol. 2018 Aug; 28(8):3393-3404.
Score: 0.024
-
Beam-hardening in 70-kV Coronary CT angiography: Artifact reduction using an advanced post-processing algorithm. Eur J Radiol. 2018 Apr; 101:111-117.
Score: 0.024
-
Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality. J Cardiovasc Comput Tomogr. 2017 Sep - Oct; 11(5):354-359.
Score: 0.023
-
Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique. AJR Am J Roentgenol. 2017 Aug; 209(2):370-379.
Score: 0.023
-
CT coronary calcium scoring with tin filtration using iterative beam-hardening calcium correction reconstruction. Eur J Radiol. 2017 Jun; 91:29-34.
Score: 0.023
-
CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure. Eur J Radiol. 2017 Jan; 86:276-283.
Score: 0.022
-
Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection. Acad Radiol. 2016 12; 23(12):1480-1489.
Score: 0.022
-
Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy. Invest Radiol. 2016 Feb; 51(2):139-46.
Score: 0.021
-
Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study. Eur J Radiol. 2016 Jan; 85(1):39-47.
Score: 0.021
-
Quantification of myocardial viability distribution with Gd(DTPA) bolus-enhanced, signal intensity-based percent infarct mapping. Magn Reson Imaging. 2011 Jun; 29(5):650-8.
Score: 0.015