Jeremy Gilbert to Surface Properties
This is a "connection" page, showing publications Jeremy Gilbert has written about Surface Properties.
Connection Strength
3.524
-
Cathodic activation and inflammatory species are critical to simulating in vivo Ti-6Al-4V selective dissolution. Acta Biomater. 2022 09 01; 149:399-409.
Score: 0.182
-
Corrosion properties of low carbon CoCrMo and additively manufactured CoCr alloys for dental applications. Dent Mater. 2022 07; 38(7):1184-1193.
Score: 0.181
-
In Vitro Corrosion Assessment of the Essure? Medical Device in Saline, Simulated Inflammatory Solution and Neutral Buffered Formalin. Acta Biomater. 2022 07 15; 147:414-426.
Score: 0.180
-
Interfacial compliance, energy dissipation, frequency effects, and long-term fretting corrosion performance of Ti-6Al-4V/CoCrMo interfaces. J Biomed Mater Res A. 2022 02; 110(2):409-423.
Score: 0.171
-
The effect of hypochlorous acid on the tribocorrosion of CoCrMo/Ti-6Al-4V bearing couples. J Biomed Mater Res A. 2021 12; 109(12):2536-2544.
Score: 0.170
-
Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy. ACS Biomater Sci Eng. 2020 03 09; 6(3):1344-1354.
Score: 0.154
-
Electrochemical potential zone of viability on CoCrMo surfaces is affected by cell type: Macrophages under cathodic bias are more resistant to killing. J Biomed Mater Res A. 2019 03; 107(3):526-534.
Score: 0.142
-
The effect of the inflammatory species hypochlorous acid on the corrosion and surface damage of Ti-6Al-4V and CoCrMo alloys. J Biomed Mater Res A. 2018 12; 106(12):3185-3194.
Score: 0.139
-
Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5?40' Mixed Alloy Modular Taper Junctions. J Arthroplasty. 2018 06; 33(6):1953-1961.
Score: 0.134
-
Voltage and wear debris from Ti-6Al-4V interact to affect cell viability during in-vitro fretting corrosion. J Biomed Mater Res A. 2018 Jan; 106(1):160-167.
Score: 0.131
-
Electrosurgery Induced Damage to Ti-6Al-4V and CoCrMo Alloy Surfaces in Orthopedic Implants In?Vivo and In?Vitro. J Arthroplasty. 2017 11; 32(11):3533-3538.
Score: 0.128
-
Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket. Clin Orthop Relat Res. 2016 Nov; 474(11):2414-2427.
Score: 0.123
-
The effect of cathodic electrochemical potential of Ti-6Al-4V on cell viability: voltage threshold and time dependence. J Biomed Mater Res B Appl Biomater. 2013 Nov; 101(8):1489-97.
Score: 0.098
-
Voltage-controlled cellular viability of preosteoblasts on polarized cpTi with varying surface oxide thickness. Bioelectrochemistry. 2013 Dec; 94:53-60.
Score: 0.097
-
Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces. J Biomed Mater Res A. 2013 Sep; 101(9):2602-12.
Score: 0.095
-
Fretting corrosion of CoCrMo and Ti6Al4V interfaces. Biomaterials. 2012 Aug; 33(22):5487-503.
Score: 0.090
-
Microscale and nanoscale surface strain mapping of single asperity wear in ultra high molecular weight polyethylene: Effects of materials, load, and asperity geometry. J Biomed Mater Res A. 2010 Jun 15; 93(4):1442-53.
Score: 0.079
-
Titanium is not "the most biocompatible metal" under cathodic potential: The relationship between voltage and MC3T3 preosteoblast behavior on electrically polarized cpTi surfaces. J Biomed Mater Res A. 2010 Jun 15; 93(4):1500-9.
Score: 0.079
-
A time-based potential step analysis of electrochemical impedance incorporating a constant phase element: a study of commercially pure titanium in phosphate buffered saline. J Biomed Mater Res A. 2010 May; 93(2):576-84.
Score: 0.078
-
The electrochemical impedance of polarized 316L stainless steel: structure-property-adsorption correlation. J Biomed Mater Res A. 2009 Jul; 90(1):121-32.
Score: 0.074
-
Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):162-73.
Score: 0.071
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.071
-
Quantification of fibrinogen adsorption onto 316L stainless steel. J Biomed Mater Res A. 2007 May; 81(2):465-73.
Score: 0.064
-
Micromechanics of shelf-aged and retrieved UHMWPE tibial inserts: indentation testing, oxidative profiling, and thickness effects. J Biomed Mater Res B Appl Biomater. 2005 Oct; 75(1):113-21.
Score: 0.057
-
Hot compaction of poly(methyl methacrylate) composites based on fiber shrinkage results. J Mater Sci Mater Med. 2005 Oct; 16(10):967-75.
Score: 0.057
-
Gentamicin release from two-solution and powder-liquid poly(methyl methacrylate)-based bone cements by using novel pH method. J Biomed Mater Res A. 2004 Jun 01; 69(3):577-83.
Score: 0.052
-
The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys. Biomaterials. 2004 Feb; 25(5):851-64.
Score: 0.051
-
Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium. J Biomed Mater Res A. 2003 Dec 01; 67(3):702-12.
Score: 0.050
-
In situ imaging and impedance measurements of titanium surfaces using AFM and SPIS. Biomaterials. 2003 May; 24(11):1837-52.
Score: 0.048
-
In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater. 2003 Feb 15; 64(2):78-93.
Score: 0.048
-
Surface micromechanics of ultrahigh molecular weight polyethylene: Microindentation testing, crosslinking, and material behavior. J Biomed Mater Res. 2002 Aug; 61(2):270-81.
Score: 0.046
-
Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement. J Biomed Mater Res. 2002 Mar 05; 59(3):411-21.
Score: 0.044
-
Transient electric fields induced by mechanically assisted corrosion of Ti-6Al-4V. J Biomed Mater Res. 2001 Aug; 56(2):184-94.
Score: 0.043
-
A novel high-viscosity, two-solution acrylic bone cement: effect of chemical composition on properties. J Biomed Mater Res. 1999 Oct; 47(1):36-45.
Score: 0.038
-
The effect of tibial stem design on component micromotion in knee arthroplasty. Clin Orthop Relat Res. 1997 Dec; (345):44-52.
Score: 0.033
-
Fracture of an acetabular component inserted without cement. A case report. J Bone Joint Surg Am. 1997 Jun; 79(6):901-5.
Score: 0.032
-
Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion. Clin Orthop Relat Res. 2016 Apr; 474(4):985-94.
Score: 0.029
-
Bond characteristics of porcelain fused to milled titanium. Dent Mater. 1994 Mar; 10(2):134-40.
Score: 0.026
-
Incorporation of Ca and P on anodized titanium surface: Effect of high current density. Mater Sci Eng C Mater Biol Appl. 2014 Apr 01; 37:223-31.
Score: 0.025
-
Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am. 1994 Jan; 76(1):110-5.
Score: 0.025
-
Hardness test of two titanium ceramometals. Northwest Dent Res. 1994; 4(2):11-2.
Score: 0.025
-
A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses. J Biomech. 1992 Apr; 25(4):329-40.
Score: 0.022
-
The scanning potential microscope: An instrument to image micro-corrosion processes on metallic biomaterials surfaces. Northwest Dent Res. 1991; 2(2):11-6.
Score: 0.021
-
Shear strength of composite bonded to Er:YAG laser-prepared dentin. J Dent Res. 1996 Jan; 75(1):599-605.
Score: 0.007
-
Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy. J Prosthet Dent. 1995 Jan; 73(1):17-25.
Score: 0.007
-
Four-point bend fatigue of Simplex-P and the Simplex-P/bone interface. Northwest Dent Res. 1991; 3(1):18-9.
Score: 0.005