Jeremy Gilbert to Humans
This is a "connection" page, showing publications Jeremy Gilbert has written about Humans.
Connection Strength
0.707
-
Predicting Corrosion Damage in the Human Body Using Artificial Intelligence: In?Vitro Progress and Future Applications. Orthop Clin North Am. 2023 Apr; 54(2):169-192.
Score: 0.032
-
Cathodic activation and inflammatory species are critical to simulating in vivo Ti-6Al-4V selective dissolution. Acta Biomater. 2022 09 01; 149:399-409.
Score: 0.031
-
In Vitro Corrosion Assessment of the Essure? Medical Device in Saline, Simulated Inflammatory Solution and Neutral Buffered Formalin. Acta Biomater. 2022 07 15; 147:414-426.
Score: 0.031
-
Long-term fretting corrosion performance of modular head-neck junctions with self-reinforced composite gaskets from PEEK and UHMWPE. J Mech Behav Biomed Mater. 2022 05; 129:105149.
Score: 0.030
-
CORR Insights?: Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2097-2099.
Score: 0.029
-
Nontribological corrosion modes dominate wrought CoCrMo acetabular taper corrosion: A retrieval study. J Biomed Mater Res B Appl Biomater. 2021 12; 109(12):2000-2013.
Score: 0.029
-
Self-reinforced poly(ether ether ketone) and polyethylene composite gaskets for prevention of mechanically-assisted corrosion in modular taper junctions: Seating, micromotion and short-term fretting corrosion. J Mech Behav Biomed Mater. 2021 07; 119:104454.
Score: 0.028
-
In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: Debris generation, chemistry and distribution. Acta Biomater. 2020 09 15; 114:449-459.
Score: 0.027
-
Fretting corrosion of Si3 N4 vs CoCrMo femoral heads on Ti-6Al-V trunnions. J Orthop Res. 2020 07; 38(7):1617-1626.
Score: 0.026
-
In vitro test methods for seating and fretting corrosion behavior of modular metal-on-metal acetabular tapers. J Orthop Res. 2020 05; 38(5):1089-1100.
Score: 0.026
-
Fretting initiated crevice corrosion of 316LVM stainless steel in physiological phosphate buffered saline: Potential and cycles to initiation. Acta Biomater. 2019 10 01; 97:565-577.
Score: 0.025
-
Electrochemical potential zone of viability on CoCrMo surfaces is affected by cell type: Macrophages under cathodic bias are more resistant to killing. J Biomed Mater Res A. 2019 03; 107(3):526-534.
Score: 0.024
-
The effect of the inflammatory species hypochlorous acid on the corrosion and surface damage of Ti-6Al-4V and CoCrMo alloys. J Biomed Mater Res A. 2018 12; 106(12):3185-3194.
Score: 0.024
-
In vitro cytotoxicity of galvanically coupled magnesium-titanium particles on human osteosarcoma SAOS2 cells: A potential cancer therapy. J Biomed Mater Res B Appl Biomater. 2019 01; 107(1):178-189.
Score: 0.023
-
Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5?40' Mixed Alloy Modular Taper Junctions. J Arthroplasty. 2018 06; 33(6):1953-1961.
Score: 0.023
-
Electrosurgery Induced Damage to Ti-6Al-4V and CoCrMo Alloy Surfaces in Orthopedic Implants In?Vivo and In?Vitro. J Arthroplasty. 2017 11; 32(11):3533-3538.
Score: 0.022
-
Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty. J Arthroplasty. 2016 12; 31(12):2900-2906.
Score: 0.020
-
Effect of mixed alloy combinations on fretting corrosion performance of spinal screw and rod implants. J Biomed Mater Res B Appl Biomater. 2017 07; 105(5):1169-1177.
Score: 0.020
-
Primary hip replacement stem taper fracture due to corrosion in 3 patients. Acta Orthop. 2016; 87(2):189-92.
Score: 0.020
-
The Arc of Scientific Journals - 50 Years of Publishing: 1985-2035. J Biomed Mater Res B Appl Biomater. 2016 Jan; 104(1):7.
Score: 0.020
-
Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res A. 2015 Jan; 103(1):211-23.
Score: 0.017
-
Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces. J Biomed Mater Res A. 2013 Sep; 101(9):2602-12.
Score: 0.016
-
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
Score: 0.015
-
Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):162-73.
Score: 0.012
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.012
-
Quantification of fibrinogen adsorption onto 316L stainless steel. J Biomed Mater Res A. 2007 May; 81(2):465-73.
Score: 0.011
-
Micromechanics of shelf-aged and retrieved UHMWPE tibial inserts: indentation testing, oxidative profiling, and thickness effects. J Biomed Mater Res B Appl Biomater. 2005 Oct; 75(1):113-21.
Score: 0.010
-
Gentamicin release from two-solution and powder-liquid poly(methyl methacrylate)-based bone cements by using novel pH method. J Biomed Mater Res A. 2004 Jun 01; 69(3):577-83.
Score: 0.009
-
In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater. 2003 Feb 15; 64(2):78-93.
Score: 0.008
-
Surface micromechanics of ultrahigh molecular weight polyethylene: Microindentation testing, crosslinking, and material behavior. J Biomed Mater Res. 2002 Aug; 61(2):270-81.
Score: 0.008
-
A theoretical and experimental analysis of polymerization shrinkage of bone cement: A potential major source of porosity. J Biomed Mater Res. 2000 Oct; 52(1):210-8.
Score: 0.007
-
Effect of multipurpose care solutions upon physical dimensions of silicone hydrogel contact lenses. J Biomed Mater Res B Appl Biomater. 2020 07; 108(5):1915-1924.
Score: 0.006
-
The effect of tibial stem design on component micromotion in knee arthroplasty. Clin Orthop Relat Res. 1997 Dec; (345):44-52.
Score: 0.006
-
Fracture of an acetabular component inserted without cement. A case report. J Bone Joint Surg Am. 1997 Jun; 79(6):901-5.
Score: 0.005
-
Does Taper Size Have an Effect on Taper Damage in Retrieved Metal-on-Polyethylene Total Hip Devices? J Arthroplasty. 2016 09; 31(9 Suppl):277-81.
Score: 0.005
-
Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion. Clin Orthop Relat Res. 2016 Apr; 474(4):985-94.
Score: 0.005
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.005
-
Mechanically assisted taper corrosion in modular TKA. J Arthroplasty. 2014 Sep; 29(9 Suppl):205-8.
Score: 0.004
-
Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am. 1994 Jan; 76(1):110-5.
Score: 0.004
-
PMMA brush-containing two-solution bone cement: preparation, characterization, and influence of composition on cement properties. J Mater Sci Mater Med. 2014 Jan; 25(1):79-89.
Score: 0.004
-
Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study. J Arthroplasty. 2013 Sep; 28(8 Suppl):2-6.
Score: 0.004
-
Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013 Oct; 471(10):3270-82.
Score: 0.004
-
Intraoperative neuromonitoring: can the results of direct stimulation of titanium-alloy pedicle screws in the thoracic spine be trusted? J Clin Neurophysiol. 2012 Dec; 29(6):502-8.
Score: 0.004
-
A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses. J Biomech. 1992 Apr; 25(4):329-40.
Score: 0.004
-
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002 Aug; (401):149-61.
Score: 0.002
-
Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail. J Bone Joint Surg Am. 2001 Apr; 83(4):537-48.
Score: 0.002
-
Corrosion of metal orthopaedic implants. J Bone Joint Surg Am. 1998 Feb; 80(2):268-82.
Score: 0.001
-
Comparison of chemical analysis of residual monomer in a chemical-cured dental acrylic material to an FTIR method. Dent Mater. 1997 Jul; 13(4):240-5.
Score: 0.001
-
Shear strength of composite bonded to Er:YAG laser-prepared dentin. J Dent Res. 1996 Jan; 75(1):599-605.
Score: 0.001
-
Local and distant products from modularity. Clin Orthop Relat Res. 1995 Oct; (319):94-105.
Score: 0.001
-
Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J Bone Joint Surg Am. 1994 Sep; 76(9):1345-59.
Score: 0.001
-
Composition and morphology of wear debris in failed uncemented total hip replacement. J Bone Joint Surg Br. 1994 Jan; 76(1):60-7.
Score: 0.001