Jeremy Gilbert to Stress, Mechanical
This is a "connection" page, showing publications Jeremy Gilbert has written about Stress, Mechanical.
Connection Strength
1.165
-
Design, Material, and Seating Load Effects on In?Vitro Fretting Corrosion Performance of Modular Head-Neck Tapers. J Arthroplasty. 2019 05; 34(5):991-1002.
Score: 0.152
-
Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5?40' Mixed Alloy Modular Taper Junctions. J Arthroplasty. 2018 06; 33(6):1953-1961.
Score: 0.142
-
Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method. J Biomed Mater Res. 1997 Dec 05; 37(3):421-31.
Score: 0.140
-
Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket. Clin Orthop Relat Res. 2016 Nov; 474(11):2414-2427.
Score: 0.130
-
Microscale and nanoscale surface strain mapping of single asperity wear in ultra high molecular weight polyethylene: Effects of materials, load, and asperity geometry. J Biomed Mater Res A. 2010 Jun 15; 93(4):1442-53.
Score: 0.084
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.076
-
Complexity in modeling of residual stresses and strains during polymerization of bone cement: effects of conversion, constraint, heat transfer, and viscoelastic property changes. J Biomed Mater Res A. 2006 Dec 15; 79(4):999-1014.
Score: 0.066
-
Hot compaction of poly(methyl methacrylate) composites based on fiber shrinkage results. J Mater Sci Mater Med. 2005 Oct; 16(10):967-75.
Score: 0.060
-
In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater. 2003 Feb 15; 64(2):78-93.
Score: 0.050
-
Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement. J Biomed Mater Res. 2002 Mar 05; 59(3):411-21.
Score: 0.047
-
The effect of tibial stem design on component micromotion in knee arthroplasty. Clin Orthop Relat Res. 1997 Dec; (345):44-52.
Score: 0.035
-
Fracture of an acetabular component inserted without cement. A case report. J Bone Joint Surg Am. 1997 Jun; 79(6):901-5.
Score: 0.034
-
Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion. Clin Orthop Relat Res. 2016 Apr; 474(4):985-94.
Score: 0.031
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.028
-
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res. 1993 Dec; 27(12):1533-44.
Score: 0.027
-
Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013 Oct; 471(10):3270-82.
Score: 0.026
-
A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses. J Biomech. 1992 Apr; 25(4):329-40.
Score: 0.024
-
Shear strength of composite bonded to Er:YAG laser-prepared dentin. J Dent Res. 1996 Jan; 75(1):599-605.
Score: 0.008
-
Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy. J Prosthet Dent. 1995 Jan; 73(1):17-25.
Score: 0.007