Item Type | Name |
Academic Article
|
[Technical bases and acquisition conditions of electron-beam computed tomography].
|
Academic Article
|
CT of coronary artery disease.
|
Academic Article
|
CT angiography with multidetector-row CT for detection of acute pulmonary embolus.
|
Academic Article
|
Multi-detector row CT systems and image-reconstruction techniques.
|
Academic Article
|
Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography.
|
Academic Article
|
Pediatric superior vena cava syndrome: assessment at low radiation dose 64-slice CT angiography.
|
Academic Article
|
Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation.
|
Academic Article
|
[Coronary CT angiography using prospective ECG triggering: high diagnostic accuracy with low radiation dose].
|
Academic Article
|
Coronary artery dilation in LEOPARD syndrome: surveillance with low radiation dose cardiac CT.
|
Academic Article
|
Radiation dose at coronary CT angiography: second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT.
|
Academic Article
|
Iterative image reconstruction techniques: Applications for cardiac CT.
|
Academic Article
|
Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT.
|
Academic Article
|
CT detection of pulmonary embolism and aortic dissection.
|
Academic Article
|
Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection.
|
Academic Article
|
Progressive intra-individual radiation dose reduction during CT surveillance of a patient with ALCAPA syndrome.
|
Academic Article
|
CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.
|
Academic Article
|
Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography.
|
Academic Article
|
CT coronary angiography: image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection.
|
Academic Article
|
Dual-energy CT: radiation dose aspects.
|
Academic Article
|
Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography.
|
Academic Article
|
Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.
|
Academic Article
|
Advances in cardiac imaging with 16-section CT systems.
|
Academic Article
|
Predictive value of zero calcium score and low-end percentiles for the presence of significant coronary artery stenosis in stable patients with suspected coronary artery disease.
|
Academic Article
|
[Value of electron beam tomography (EBT)].
|
Academic Article
|
Novel developments in cardiac computed tomography.
|
Academic Article
|
Coronary CT angiography.
|
Academic Article
|
Multidetector CT of the paranasal sinus: potential for radiation dose reduction.
|
Academic Article
|
Cardiac CT in the assessment of acute chest pain in the emergency department.
|
Academic Article
|
CT of coronary artery disease.
|
Academic Article
|
Benefits versus risks of computed tomography: tipping the balance.
|
Academic Article
|
Computing effective dose in cardiac CT.
|
Academic Article
|
Dual-energy computed tomography for integrative imaging of coronary artery disease: principles and clinical applications.
|
Academic Article
|
Radiation dose at cardiac computed tomography: facts and fiction.
|
Academic Article
|
Practical strategies for low radiation dose cardiac computed tomography.
|
Academic Article
|
Radiation-related cancer risks in a clinical patient population undergoing cardiac CT.
|
Academic Article
|
Expert opinion: Radiation dose management in cardiopulmonary imaging.
|
Academic Article
|
Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection.
|
Academic Article
|
Quantification of left and right ventricular function and myocardial mass: comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI.
|
Academic Article
|
Developmental aortic arch anomalies in infants and children assessed with CT angiography.
|
Academic Article
|
Coronary CT angiography: comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT-Initial experience.
|
Academic Article
|
Dual-energy CT imaging of thoracic malignancies.
|
Academic Article
|
Iterative image reconstruction: a realistic dose-saving method in cardiac CT imaging?
|
Concept
|
Radiation Injuries
|
Concept
|
Radiation Dosage
|
Concept
|
Radiation Protection
|
Concept
|
Neoplasms, Radiation-Induced
|
Academic Article
|
Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.
|
Academic Article
|
Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.
|
Academic Article
|
First-arterial-pass dual-energy CT for assessment of myocardial blood supply: do we need rest, stress, and delayed acquisition? Comparison with SPECT.
|
Academic Article
|
Diagnostic accuracy of coronary CT angiography: comparison of filtered back projection and iterative reconstruction with different strengths.
|
Academic Article
|
Iterative image reconstruction techniques: cardiothoracic computed tomography applications.
|
Academic Article
|
Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.
|
Academic Article
|
Low tube voltage and low contrast material volume cerebral CT angiography.
|
Academic Article
|
Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.
|
Academic Article
|
Closing in on the K edge: coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second- versus a third-generation dual-source CT system.
|
Academic Article
|
Image quality and radiation dose of lower extremity CT angiography using 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction.
|
Academic Article
|
CT dose reduction using prospectively triggered or fast-pitch spiral technique employed in cardiothoracic imaging (the CT dose study).
|
Academic Article
|
Incremental value of pharmacological stress cardiac dual-energy CT over coronary CT angiography alone for the assessment of coronary artery disease in a high-risk population.
|
Academic Article
|
Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.
|
Academic Article
|
Radiation risks from cardiovascular imaging tests.
|
Academic Article
|
Reply: the ethics of publishing dual exposure scans involving ionizing radiation when validated alternatives exist.
|
Academic Article
|
High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols.
|
Academic Article
|
ECG-synchronized CT angiography in 324 consecutive pediatric patients: spectrum of indications and trends in radiation dose.
|
Academic Article
|
Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography.
|
Academic Article
|
Seventy-Peak Kilovoltage High-Pitch Thoracic Aortic CT Angiography without ECG Gating: Evaluation of Image Quality and Radiation Dose.
|
Academic Article
|
Low-volume contrast medium protocol for comprehensive cardiac and aortoiliac CT assessment in the context of transcatheter aortic valve replacement.
|
Academic Article
|
Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70?kVp in a clinical setting: comparison with invasive coronary angiography.
|
Academic Article
|
Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study.
|
Academic Article
|
Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison.
|
Academic Article
|
Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction.
|
Academic Article
|
Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT.
|
Academic Article
|
Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning.
|
Academic Article
|
Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection.
|
Academic Article
|
State-of-the-Art Pulmonary CT Angiography for Acute Pulmonary Embolism.
|
Academic Article
|
Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration.
|
Academic Article
|
Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.
|
Academic Article
|
Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population.
|
Academic Article
|
Radiation Optimized Dual-source Dual-energy Computed Tomography Pulmonary Angiography: Intra-individual and Inter-individual Comparison.
|
Academic Article
|
CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure.
|
Academic Article
|
Coronary artery calcium in breast cancer survivors after radiation therapy.
|
Academic Article
|
High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.
|
Academic Article
|
White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 2: Radiation Dose and Iodine Sensitivity.
|
Academic Article
|
Ultralow-radiation-dose chest CT: accuracy for lung densitometry and emphysema detection.
|
Academic Article
|
Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: results of the prospective multicenter REALISE trial.
|
Academic Article
|
Radiation Dose Levels of Retrospectively ECG-Gated Coronary CT Angiography Using 70-kVp Tube Voltage in Patients with High or Irregular Heart Rates.
|
Academic Article
|
Prospectively ECG-triggered high-pitch 80?kVp coronary computed tomography angiography with 30?mL of 270?mg I/mL contrast material and iterative reconstruction.
|
Academic Article
|
CT coronary calcium scoring with tin filtration using iterative beam-hardening calcium correction reconstruction.
|
Academic Article
|
70-kVp High-pitch Computed Tomography Pulmonary Angiography with 40 mL Contrast Agent: Initial Experience.
|
Academic Article
|
Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale.
|
Academic Article
|
Non-Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction: Initial Results.
|
Academic Article
|
Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality.
|
Academic Article
|
Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.
|
Academic Article
|
Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.
|
Academic Article
|
Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.
|
Academic Article
|
Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT.
|
Academic Article
|
High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction.
|
Academic Article
|
Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography.
|
Academic Article
|
The effect of abdominal contrast-enhanced CT on DNA double-strand breaks in peripheral blood lymphocytes: an in vitro and in vivo study.
|
Academic Article
|
The value of Coronary Artery computed Tomography as the first-line anatomical test for stable patients with indications for invasive angiography due to suspected Coronary Artery Disease: CAT-CAD randomized trial.
|
Academic Article
|
Feasibility of extracellular volume quantification using dual-energy CT.
|
Academic Article
|
Coronary CT angiography radiation dose trends: A 10-year analysis to develop institutional diagnostic reference levels.
|
Academic Article
|
Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm.
|
Academic Article
|
Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography.
|
Academic Article
|
The Feasibility, Tolerability, Safety, and Accuracy of Low-radiation Dynamic Computed Tomography Myocardial Perfusion Imaging With Regadenoson Compared With Single-photon Emission Computed Tomography.
|
Concept
|
Absorption, Radiation
|
Concept
|
Radiation Exposure
|