Search Result Details

This page shows the details of why an item matched the keywords from your search.
One or more keywords matched the following items that are connected to De Cecco, Carlo
Item TypeName
Concept Radiation Injuries
Concept Radiation Dosage
Concept Radiation Protection
Concept Neoplasms, Radiation-Induced
Academic Article Cardiovascular dual source computed tomography for aortic coarctation in a neonate: one-second scan with ultra-low radiation dose.
Academic Article Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images.
Academic Article The optimal contrast media policy in CT of the liver. Part II: Clinical protocols.
Academic Article The optimal contrast media policy in CT of the liver. Part I: Technical notes.
Academic Article Virtual unenhanced images of the abdomen with second-generation dual-source dual-energy computed tomography: image quality and liver lesion detection.
Academic Article Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64- and 128-row single-energy acquisition.
Academic Article Physician preference between low-dose computed tomography with a sinogram-affirmed iterative reconstruction algorithm and routine-dose computed tomography with filtered back projection in abdominopelvic imaging.
Academic Article Dual-source CT coronary angiography: prospective versus retrospective acquisition technique.
Academic Article First-arterial-pass dual-energy CT for assessment of myocardial blood supply: do we need rest, stress, and delayed acquisition? Comparison with SPECT.
Academic Article Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.
Academic Article Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.
Academic Article Incremental value of pharmacological stress cardiac dual-energy CT over coronary CT angiography alone for the assessment of coronary artery disease in a high-risk population.
Academic Article Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.
Academic Article Radiation risks from cardiovascular imaging tests.
Academic Article High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols.
Academic Article Low-volume contrast medium protocol for comprehensive cardiac and aortoiliac CT assessment in the context of transcatheter aortic valve replacement.
Academic Article Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study.
Academic Article Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison.
Academic Article Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction.
Academic Article Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT.
Academic Article Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning.
Academic Article Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection.
Academic Article State-of-the-Art Pulmonary CT Angiography for Acute Pulmonary Embolism.
Academic Article Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration.
Academic Article Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.
Academic Article Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population.
Academic Article CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure.
Academic Article White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 2: Radiation Dose and Iodine Sensitivity.
Academic Article CT coronary calcium scoring with tin filtration using iterative beam-hardening calcium correction reconstruction.
Academic Article Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale.
Academic Article Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality.
Academic Article Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.
Academic Article Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.
Academic Article High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction.
Academic Article Feasibility of extracellular volume quantification using dual-energy CT.
Academic Article The Feasibility, Tolerability, Safety, and Accuracy of Low-radiation Dynamic Computed Tomography Myocardial Perfusion Imaging With Regadenoson Compared With Single-photon Emission Computed Tomography.
Concept Absorption, Radiation
Concept Radiation Exposure
Search Criteria
  • Radiation