"Cardiography, Impedance" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
A type of impedance plethysmography in which bioelectrical impedance is measured between electrodes positioned around the neck and around the lower thorax. It is used principally to calculate stroke volume and cardiac volume, but it is also related to myocardial contractility, thoracic fluid content, and circulation to the extremities.
Descriptor ID |
D002307
|
MeSH Number(s) |
E01.370.370.380.160 E01.370.370.610.610.200
|
Concept/Terms |
Cardiography, Impedance- Cardiography, Impedance
- Impedance Plethysmography, Transthoracic
- Impedance Plethysmographies, Transthoracic
- Plethysmographies, Transthoracic Impedance
- Transthoracic Impedance Plethysmographies
- Impedance, Transthoracic
- Impedances, Transthoracic
- Transthoracic Impedance
- Transthoracic Impedances
- Transthoracic Impedance Plethysmography
- Plethysmography, Impedance, Transthoracic
- Impedance Cardiography
- Cardiographies, Impedance
- Impedance Cardiographies
- Plethysmography, Transthoracic Impedance
|
Below are MeSH descriptors whose meaning is more general than "Cardiography, Impedance".
Below are MeSH descriptors whose meaning is more specific than "Cardiography, Impedance".
This graph shows the total number of publications written about "Cardiography, Impedance" by people in this website by year, and whether "Cardiography, Impedance" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
1994 | 0 | 1 | 1 |
1996 | 0 | 2 | 2 |
2007 | 1 | 0 | 1 |
2014 | 1 | 0 | 1 |
2015 | 1 | 1 | 2 |
To return to the timeline,
click here.
Below are the most recent publications written about "Cardiography, Impedance" by people in Profiles.
-
Zile MR, Sharma V, Johnson JW, Warman EN, Baicu CF, Bennett TD. Prediction of All-Cause Mortality Based on the Direct Measurement of Intrathoracic Impedance. Circ Heart Fail. 2016 Jan; 9(1):e002543.
-
Dudenbostel T, Acelajado MC, Pisoni R, Li P, Oparil S, Calhoun DA. Refractory Hypertension: Evidence of Heightened Sympathetic Activity as a Cause of Antihypertensive Treatment Failure. Hypertension. 2015 Jul; 66(1):126-33.
-
Heist EK, Herre JM, Binkley PF, Van Bakel AB, Porterfield JG, Porterfield LM, Qu F, Turkel M, Pavri BB. Analysis of different device-based intrathoracic impedance vectors for detection of heart failure events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring study). Am J Cardiol. 2014 Oct 15; 114(8):1249-56.
-
Ferrario CM, Basile J, Bestermann W, Frohlich E, Houston M, Lackland DT, Smith RD, Wise DL. The role of noninvasive hemodynamic monitoring in the evaluation and treatment of hypertension. Ther Adv Cardiovasc Dis. 2007 Dec; 1(2):113-8.
-
Scardo J, Kiser R, Dillon A, Brost B, Newman R. Hemodynamic comparison of mild and severe preeclampsia: concept of stroke systemic vascular resistance index. J Matern Fetal Med. 1996 Sep-Oct; 5(5):268-72.
-
Musante L, Turner JR, Treiber FA, Davis H, Strong WB. Moderators of ethnic differences in vasoconstrictive reactivity in youth. Ethn Dis. 1996; 6(3-4):224-34.
-
Dysart JM, Treiber FA, Pflieger K, Davis H, Strong WB. Ethnic differences in the myocardial and vascular reactivity to stress in normotensive girls. Am J Hypertens. 1994 Jan; 7(1):15-22.
-
Spinale FG, Hendrick DA, Crawford FA, Carabello BA. Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure. Cardiovasc Res. 1990 May; 24(5):423-9.
-
Spinale FG, Smith AC, Crawford FA. Relationship of bioimpedance to thermodilution and echocardiographic measurements of cardiac function. Crit Care Med. 1990 Apr; 18(4):414-8.
-
Spinale FG, Reines HD, Cook MC, Crawford FA. Noninvasive estimation of extravascular lung water using bioimpedance. J Surg Res. 1989 Dec; 47(6):535-40.