"Implants, Experimental" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Artificial substitutes for body parts and materials inserted into organisms during experimental studies.
Descriptor ID |
D020007
|
MeSH Number(s) |
E07.695.340
|
Concept/Terms |
|
Below are MeSH descriptors whose meaning is more general than "Implants, Experimental".
Below are MeSH descriptors whose meaning is more specific than "Implants, Experimental".
This graph shows the total number of publications written about "Implants, Experimental" by people in this website by year, and whether "Implants, Experimental" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
1998 | 1 | 0 | 1 |
1999 | 1 | 1 | 2 |
2000 | 0 | 1 | 1 |
2004 | 3 | 0 | 3 |
2005 | 1 | 0 | 1 |
2006 | 0 | 1 | 1 |
2011 | 1 | 0 | 1 |
2014 | 0 | 1 | 1 |
2016 | 1 | 0 | 1 |
To return to the timeline,
click here.
Below are the most recent publications written about "Implants, Experimental" by people in Profiles.
-
Effect of mixed alloy combinations on fretting corrosion performance of spinal screw and rod implants. J Biomed Mater Res B Appl Biomater. 2017 07; 105(5):1169-1177.
-
The performance of cross-linked acellular arterial scaffolds as vascular grafts; pre-clinical testing in direct and isolation loop circulatory models. Biomaterials. 2014 Aug; 35(24):6311-22.
-
Intraoperative fabrication of bone tamps for indirect reduction of depressed articular segments. Orthopedics. 2011 Dec; 34(12):970-4.
-
Biomechanical and histomorphometric analyses of monocortical screws at placement and 6 weeks postinsertion. J Oral Implantol. 2006; 32(3):110-6.
-
Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofacial Orthop. 2005 Mar; 127(3):307-13.
-
Osteogenic protein-1 enhances osseointegration of titanium implants coated with peri-apatite in rabbit femoral defect. J Biomed Mater Res B Appl Biomater. 2004 Nov 15; 71(2):408-13.
-
Electromechanical impedance sensor for in vivo monitoring the body reaction to implants. J Invest Surg. 2004 Sep-Oct; 17(5):257-70.
-
The effect of seprafilm and interceed on capsule formation around silicone discs in a rat model. J Invest Surg. 2004 Sep-Oct; 17(5):271-81.
-
Inhibition of matrix metalloproteinase activity attenuates tenascin-C production and calcification of implanted purified elastin in rats. Am J Pathol. 2000 Sep; 157(3):885-93.
-
Elastin calcification and its prevention with aluminum chloride pretreatment. Am J Pathol. 1999 Sep; 155(3):973-82.